SPECIALTY GAS MANIFOLDS - HBAD2 Manual
specs HBAD2 Technical Data Sheet
High Purity Brass Manifolds:
 
• Stainless steel diaphragm regulators.
• Helium leak rate integrity 2 x 10-6 scc/sec.
• Maximum inlet pressure 3000 psig. (2000 psi for CO2 & N2O systems)
• Maximum flow rate: 200 scfh
•Delivery pressure range:
HBAD2 50–100 psig
• Manifold outlet: 1/4” OD tube.
• 1/2” Brass, silver brazed headers
• 24” flexible stainless steel lined pigtails with check valves.


Western Innovator HBAD2 manifolds are designed and manufactured for high-purity gas delivery applications requiring uninterrupted gas flow and greater cylinder capacities. User friendly and easy to operate, a simple rotation of the control knob resets the unit.

Factory-set functional components are protected inside a tamper-resistant case. A self-contained alarm system clearly indicates the system status. A green light means the service bank is functioning and the reserve bank is ready for service. A red light alerts the user that the unit has changed over and one or both banks are depleted. Dry contacts in the unit’s power supply box allow connection to remote alarms systems. (Up to 3 amps 30 VDC or 2 amps 250VAC).

Western Innovator HBAD2 provides uninterrupted high purity gas flow at an economical price. A simple adjustment of the manifold regulator is required following the system’s automatic changeover.

Design Lengths HBAD2
TOTAL NO. OF CYLINDERS
2
3
4
5
6
7
8
HBAD2 Std (10” Centers)
Overall Manifold Length
1’-6 ”
(.46m)
N/A
3’-2”
(.97m)
N/A
4’-0”
(1.47m)
N/A
6’-6”
(1.98m)
HBAD2 Staggered Design (5” Centers)
Overall Manifold Length
1’-6”
(.46m)
N/A
2’-4”
(.71m)
N/A
3’-2”
(.97m)
N/A
4’-0”
(1.96m)
HBAD2 Vertical crossover (10" Centers) Overall manifold Length
N/A
N/A
1'-6"
(.46m)
N/A
N/A
N/A

3'-2"
(.97m)

HOW TO ORDER
Specialty Manifold Ordering Instructions
Specify: Control Type (V) - Service (W) - Number
Example : HBAD2–5–6 = Model HBAD2, Helium service
CONTROL TYPE (V) GAS SERVICE (W) # OF
CYL’S (X)
HEADER
CONFIGURATION (Y)
MOUNTING (Z)
HBAD2 (30 - 100 PSIG) (1) Acetylene (POL)* CGA-510
(1A) Acetylene (Commercial)* CGA-300
(2) Zero Air CGA-346
(2A) Zero Air CGA-590
(3) Argon CGA-580
(4) Carbon Dioxide CGA-320
(5) Helium CGA-580
(6) Hydrogen CGA-350
(6A) Argon/Methane CGA-350
(7) Nitrogen CGA-580
(8) Nitrous Oxide CGA-326
(9) Oxygen CGA-540
  BLANK - Standard 10 inches on center
13 inches on center for Acetylene & LPG
V - Vertical crossover
Standard 10 inches on center
13 inches on center for Acetylene & LPG
S - Staggered 5 inches on center
6.5 inches on center for Acetylene & LPG
C - Crossover (Floor Mount Only)
Standard 10 inches on Center
13 inches on center for Acetylene & LPG
U-Shaped - Drawing Required
L-Shaped - Drawing Required
BLANK = Wall mount
F = Floor mounted

For more information, call Western Customer Service
at 1-800-783-7890 for technical data sheets

 

 


 