SPECIALTY - PF1000 PARTICLE FILTER PANELS FOR ICP & ICP-MS

Western's Purifier Panels
PF1000 SERIES
   


specs PF1000 Technical Data Sheet
DESCRIPTION

The PF1000 Series Particle Filter Panels are ideal where extreme levels of filtration are required. Our In-line filters are specifically designed to remove metals and o ther particulate matter from argon streams. Particularly suited for ICP and ICP-MS applications, the submicron filter membrane effectively removes all particles 0.01 micron or larger.

The panel mounted valves allow easy filter changeouts without an interruption of argon supply or pipeline contamination

INSTALLATION TIP
When used for ICP or ICP-MS applications, locate this panel as close as possible to the analytical equipment.



FEATURES

  • Design - Low maintenance design with convenient access to panel valves and filter.
  • By-Pass Valve - Avoids gas supply shutdowns to the point-of-use during filter changeouts.
  • Purge Valve - Allows the flushing of air and other contaminants out of the system before putting the filter back in service after filter changeouts.
  • Inlet & Outlet Valves - Their primary function is to isolate the filter during the filter replacement process.
  • Filter - 0.2 micrometer pore size membrane removes all particles 0.01 micron or larger.
  • Stainless Steel Parts - Minimizes metal and particles from being released into the gas stream.
  • Construction - Convenient complete package, easy to install with pre-drilled holes in the panel.

SPECIFICATIONS
MATERIALS OF CONSTRUCTION
Max. Operating Pressure: 1,000 PSIG
Max. Operating Temperature: 100°F
Max. Differential Pressure: 60 psi @ 70°F
Filtration Rating: 0.01 micron @100% efficiency
Max. Flow Capacity: 0.01 micron @100% efficiency
Filtration Area: 250 lpm, 15 psig to atm.
Inlet & Outlet Connections : 3/8 Compression SS
Approximate Weight: 9 lbs.
Inlet & Outlet Ball Valves:
Body Stainless Steel 316 ASTM A351 GR. CF8M
Ball Stainless Steel 316
Seats & Seals PTFE
Fittings: Type 316L Stainless Steel
Filter:
Body & Fittings Type 316L Stainless Steel
Filter Medium PTFE Teflon
O-ring Seal Teflon encapsulated silicone

HOW TO ORDER - PART NUMBER MATRIX

PF1000
-
 
-
 
SERIES TYPICAL FLUIDS

3 = Argon
5 = Helium
6 = Hydrogen
7 = Nitrogen
Other: Please specify
FILTER

 
Standard Filter: 0.01m = 0.01 micron
Optional Filters: 0.1m = 0.1 microns
2m = 2 microns
   
   




For more information, call Western Customer Service
at 1-800-783-7890 for technical data sheets

 

 


 

home | about us | distributor info | wholesalers | service providers
industrial manifolds | med manifolds | spec manifolds | manifold accessories
news | faqs | references


 
 
powered by Vertical Lift Web Designs
copyright © 2007 Western Innovator, Inc.