High Purity Regulators - HLRB Series
High Purity Brass Bar-Stock Line Regulator
   HLRB Series


DESCRIPTION

The HLRB regulators are designed to suit a large variety of high purity and general use applications where a secondary line regulator is used to provide an exacting point of use control. This regulator provides outstanding performance, but are rugged and versatile enough for the laboratory or plant applications.

FEATURES

  • Minimal internal volume
  • Seat area protected by a 10 micron filter.
  • Five delivery ranges available.
  • Stainless steel diaphragm eliminates contamination from diffusion or out gassing.
  • Body is pre-tapped and has milled flats for back panel mounting.
  • 1 x 10-9 cc/sec. inboard helium leak rate
APPLICATIONS

The HLRB series line regulators are ideally suited for use in pipeline applications of Research Purity or High Purity gases up to 5.0 purity. The high purity design makes the ideal for line drop regulators in instrumentation labs were precise pressure control is required.


SPECIFICATIONS
MATERIALS OF CONSTRUCTION
Max. Inlet Pressure: 3,000 psig
Operating Temperature Range: -20°F to 120°F
Leakage: 1 x 10-8
Flow Coefficient (CV): 0.08
Shipping Weight: 2.68 lbs.

Body: Brass Bar-stock, Chrome Plated
Bonnet: Brass Bar-stock, Chrome Plated
Diaphragm: 316L Stainless Steel
Seat: PTFE Teflon®
Seals: PTFE Teflon®
Filters: 10 Micron Sintered Bronze
Gauge: Chrome Plated Brass




Questions? — Contact Technical Sales 800.783.7890
HOW TO ORDER
HLRB Regulator Ordering Instructions
Model Selection Guide


Example: HLRB012500 = model HLRB with up to 125 psig delivery pressure, 1/4” NPT female inlet, 1/4” NPT female outlet
Model
Inlet/Outlet
Outlet Port
Inlet Connection
HLRB
Delivery Pressure Range:
Delivery Pressure Gauge:
0 = None
(1/4” NPT female)
0 = None
(1/4” NPT female)
0015 = 0-15 psig
30” Hg - 30 psig
0050 = 0-50 psig
30” Hg - 100 psig
1 = 1/4”
Compression tube fitting
1 = 1/4”
Compression tube fitting
0125 = 0-125 psig
30” Hg - 200 psig
0250 = 0-250 psig
0 - 400 psig
2 = 1/4”
Compression tube fitting
2 = 1/4”
Compression tube fitting
0500 = 0-500 psig
0 - 1000 psig

For more information, call Western Customer Service
at 1-800-783-7890 for technical data sheets

 

 


 